Stage 4 · Railings & stairs
Railings & stairs: the stage measured in inches, because falls are
Guard and stair rules exist in their exact, fussy form because each number answers a specific way people — especially children — get hurt. The IRC baseline below is what most US jurisdictions start from; local amendments govern.
Guards: when, how high, how strong
- When required: any deck surface more than 30 inches above the ground or floor below, measured within 36 inches horizontally of the edge.
- Height: at least 36 inches for single-family residential decks under the IRC (many commercial and some amended local codes require 42 inches).
- Openings: balusters or infill must reject a 4-inch sphere — the head-entrapment rule. The triangular opening at the bottom of a stair guard gets a slightly larger allowance (6-inch sphere).
- Load: guards must resist a 200-lb concentrated load at the top rail. This is why guard posts must be blocked and bolted to the framing — a post screwed to the rim board's face with deck screws is decoration, not a guard. Post-to-frame connection is the most common guard failure found on inspection.
Material notes, honestly
Wood guards match wood decks and share their maintenance. Aluminium systems are slim, strong and maintenance-light. Cable rail preserves views and is the most installation-sensitive: tension, post stiffness and the 4-inch rule under load (cables deflect — spacing is set tighter so a pushed cable still rejects the sphere) all matter, and some jurisdictions scrutinise the “ladder effect” question for horizontal infill — the IRC does not prohibit horizontal rails for single-family homes, but check locally. Glass panels are code-capable with laminated, rated glass and are a cleaning commitment near trees and grills.
Stair geometry: the numbers your knees already know
- Riser height: maximum 7¾ inches; tread depth: minimum 10 inches (nosing included per code detail). Within one flight, the tallest riser may exceed the shortest by no more than ⅜ inch — inconsistency trips people more reliably than steepness does.
- Width: 36 inches minimum clear. Headroom: 6 ft 8 in. minimum.
- Handrail: required on stairs with four or more risers, 34–38 inches above the tread nosings, continuous, and graspable — a 2×6 laid flat is a cap, not a handrail; a profiled rail or a secondary graspable rail does the job.
- Landings and gates: a level landing where a door swings over the stair, and a self-closing gate where the deck serves a pool (pool barrier rules are their own code section — stricter, and enforced).
Lighting that earns its place
Riser lights and a lit landing are safety equipment, not ambience: the two places people fall are the first step down and the last step they forgot. Low-voltage LED systems draw so little that the cost argument against them has expired. Put the transformer somewhere reachable, and photograph wire runs before the skirting goes on — future you will ask.